audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Checking Oxygen Sensor Heating|Page 4571 > < Checking Oxygen Sensor Heating
Page 1
background image

Oxygen Sensor: Testing and Inspection
Electrical Testing

SENSOR ELECTRICAL TESTS:

NOTE:  
-

G130 = O2S behind three way catalytic converter, bank 1.

-

G131 = O2S behind three way catalytic converter, bank 2.

-

Disconnect connector for O2S behind three way catalytic converter.

-

Switch multimeter (Fluke 83 or equivalent) to resistance  measuring range and connect between connector terminals 3 (GND wire) and 4 (signal
wire) of heated oxygen sensor.

If continuity is not obtained:
-

Replace heated oxygen sensor.

If continuity obtained:

-

Switch multimeter (Fluke 83 or equivalent)to 2 volt range and connect between terminals 3 (GND) and 4 (signal wire) on harness connector.

-

Switch ignition ON.

Specified Value: 400 ± 50 mV.

If the specified value is not obtained, check wiring to ECM as follows:
-

Switch ignition OFF.

-

Connect VAG 1598/19 test box to ECM wiring harness.

-

Check following wiring connections for continuity.

Specified Value: max. 1 Ohm.

If the specified value is not obtained:

Checking Oxygen Sensor Heating|Page 4571 > < Checking Oxygen Sensor Heating