Vacuum Pump: Scan Tool Testing and Procedures
Basic Setting (Performing "Short Trip" Test)

Basic setting (performing "short trip" test)

-

Press -> button until the following is indicated on the display: 

Indicated on display (function selection):

-

Press keys 0 and 4 for "Basic setting" and confirm the entry with the Q button. 

Indicated on display (function selection):

-

Press keys 0, 0 and 8 for "Perform short trip test UP 28" and confirm the entry with the Q key.

Indicated on display (function selection):

-

Press 4

-

Firmly depress the brake pedal several times in succession (venting the brake booster) until the test is activated.

Indicated on display (function selection):

-

The brake pedal must not be pressed once the test has been activated, as the pump is switched off when the brake pedal is actuated.

The pump evacuates the brake booster. The diagnosis of the brake booster system runs in parallel in the control module. The system passes the test if
the pressure in the brake booster reaches the shut-off threshold within the time limit set by the diagnostic function (max. 20 sec).

Indicated on display (function selection):

-

Press 8

-

Remove diagnosis lead from diagnostic connection. 

or:

Indicated on display (function selection):

If the test shows the system is not OK, read out the DTC memory and repair the malfunction (ignition must be switched off!).