audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fuel and Residual Pressures Before High Pressure Pump, Checking|Page 3200 > < Fuel and Residual Pressures Before High Pressure Pump, Checking|Page 3198
Page 5
background image

-

Connect assisting hose - arrow - to pressure gauge and hold it in a measuring container.

-

Open shut-off valve of pressure gauge. The lever points in the direction of flow.

-

Bleed the fuel system, by briefly pressing the remote control.

-

Close shut-off valve of pressure gauge. Lever stands perpendicular to direction of flow - arrow -.

-

Hold the switch of the remote control until no more pressure increase is observed on the fuel pressure gauge.

‹› Specified value: Approximately 6 bar positive pressure

If the specification is not obtained:

-

Check delivery quantity of fuel pump.

Residual Pressure, Checking

-

Check for leaks and for residual pressure by observing the pressure loss on the pressure gauge.

‹› After 10 minutes there must be a residual pressure of at least 3.75 bar.

If the residual pressure drops below 3.75 bar:

‹› Check connection between fuel pressure gauge and fuel line for leaks. 

‹› Check pressure gauge for leaks.

‹› Check fuel lines and their connections for leaks.

‹› Replace fuel filter with integrated fuel pressure regulator.

‹› Replace fuel pump. 

Assembly is in reverse order of removal, note the following:

‹› Before disconnecting pressure gauge, release pressure by opening shut-off valve. Hold a container in front of connection for this.

Tightening Specifications

Fuel and Residual Pressures Before High Pressure Pump, Checking|Page 3200 > < Fuel and Residual Pressures Before High Pressure Pump, Checking|Page 3198