Oxygen Sensor: Service and Repair
Oxygen Sensor After Catalytic Converter, Bank 1

Oxygen Sensor After Catalytic Converter, Bank 1

Special tools, testers and auxiliary items required

‹› Ring Spanner 7-Piece Set for Oxygen Sensor (3337 )

Removing

‹› All cable ties which are opened or cut open when removing, must be replaced in the same position when installing.

-

Pull rear engine cover off - arrows -.

-

Disconnect check valve - 1 - from connection at air duct hose.

-

Remove the air duct hose, thereby loosening the hose clamp -  2 - and opening the clips - arrows -.

-

Disconnect the electrical harness connector - 2 - for oxygen sensor after catalytic converter (G130) and free up the wiring.