Oxygen Sensor: Service and Repair
Oxygen Sensor After Catalytic Converter, Bank 2

Oxygen Sensor After Catalytic Converter, Bank 2

Special tools, testers and auxiliary items required

‹› Ring Spanner 7-Piece Set for Oxygen Sensor (3337 )

Removing

‹› All cable ties which are opened or cut open when removing, must be replaced in the same position when installing.

-

Pull rear engine cover off - arrows -.

-

Remove coolant expansion tank - arrow -.

-

Disconnect electrical connection from engine coolant level warning switch (F66) at bottom of coolant reservoir and set aside coolant reservoir
with coolant hoses - 1 - and -  2 - connected.

-

Disconnect the electrical harness connector - 1 - for oxygen sensor 2 after catalytic converter (G131) and free up the wiring.