audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fuel and Residual Pressures Before High Pressure Pump, Checking|Page 3980 > < Fuel and Residual Pressures Before High Pressure Pump, Checking
Page 2
background image

-

Connect a Hand held remote control (jumper) to terminal - 1 - of the fuel delivery unit and to vehicle battery (+).

-

Connect a jumper cable from a Electrical connector test lead set to terminal - 5 - of the fuel delivery unit and to vehicle Ground (GND).

-

Remove the rear engine cover - arrows -.

Fuel and Residual Pressures Before High Pressure Pump, Checking|Page 3980 > < Fuel and Residual Pressures Before High Pressure Pump, Checking