Connect multimeter between terminal - 3 - and - 4 - of harness connector for voltage measurement.

-

Switch ignition on.
-

Specification: approx. battery voltage.

If specification is not obtained:

-

Repair open circuit in wiring according to wiring diagram.

Check activation of Fuel Pump (FP) Control Module J538

-

For voltage testing, connect multimeter with measuring probes and connector adapters from connector test set V.A.G 1594 C between clamp - 4 -
and - 5 - , as shown in illustration. The electrical connection remains connected.

NOTE:  Connector sockets are numbered respectively on the rear side of the connector.

-

Start engine.
-

Specified value during start and while running at idle: approx. 5.0 V.

-

Depress accelerator pedal completely and then release it (brief throttle burst).
-

Specification: The voltage value must first rise slightly, then fall and then rise again to the previously read value.

If reading does not result as described:

-

Switch off ignition.

-

Connect test box V.A.G 1598/42 to wiring harness with adapter cable V.A.G 1598/39-1 or adapter cable V.A.G 1598/39-2 ; engine control
module (ECM) remains connected. Clamp test box Ground (GND) clip to battery negative terminal.

CAUTION:  To avoid damaging electronic components, set measuring range before connecting test leads and observe all test