audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Battery, Disconnecting and Connecting|Page 7821 > < Battery, Disconnecting and Connecting|Page 7819
Page 2
background image

-

Fold positive terminal cover - 2 - upward.

-

Then disconnect positive ( + ) terminal - 1 - from battery.

-

Disconnect central gas venting system hose - 7 -. 

-

Remove bolt - 4 - from battery hold-down bracket -  3 -.

-

Remove battery from battery console retaining strip.

-

Remove battery from luggage compartment.

CAUTION!
When disposing batteries it is absolutely necessary that the disposal procedures for batteries and sulfuric acid are observed.

Installing

‹› Only maintenance-free batteries conforming to standards "TL82506 " (as of December 1997) and "VW75073" (as of August 2001) may be

installed.

‹› Batteries from the Audi Parts Program have a bottom strip-adapter for adapting to different grip channels. Whether and how bottom strip-adapter

is used, refer to operating instructions for battery.

-

Insert battery in battery holder.

‹› Battery clamping strip - 1 - must engage in battery holder mount - 2 -.

‹› It should no longer be possible to move the battery.

-

Position battery hold-down bracket - 3 -.

Battery, Disconnecting and Connecting|Page 7821 > < Battery, Disconnecting and Connecting|Page 7819