‹› The greater the specific gravity of the electrolyte drawn in, the higher the float will ride.

‹› The specific gravity in kg/dm3 (specific gravity of electrolyte) can be read off the scale - arrow - on the hydrometer.

-

Take reading on hydrometer and compare to values given in table: 

The specific gravity in normal climatic zones must be at least 1.24 kg/dm3. If specific gravity is too low in all battery cells: 

-

Charge battery and then repeat electrolyte specific gravity test. 

Example 1:

*

specific gravity in cell 4 is too low (deviation greater than 0.03 kg/dm3)

Example 2: