audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Absorbent Glass Mat Battery, Checking|Page 7768 > < Absorbent Glass Mat Battery, Checking
Page 1
background image

Battery: Component Tests and General Diagnostics
Battery, Visual Inspection

Maintenance-Free Batteries

Only maintenance-free batteries conforming to standards "TL82506 " (as of December 1997) and "VW75073" (as of August 2001) may be installed.

CAUTION!
Risk of injury due to contact with battery acid!

‹› Prior to handling or servicing batteries, read, understand and observe the Warnings and Safety Measures => [ There is a risk of

injury from the battery

acid. ] See: Description and Operation/Battery.

Risk of explosion due to the explosive gas that forms during battery charging.

‹› Observe warning notes and safety precautions => [ Risk of explosion due to the explosive gas

that forms during battery charging. ] See: Description and Operation/Battery. 

Battery, Visual Inspection

-

Before performing extensive measurements, inspect visually.

‹› External battery condition;

‹› Battery connections;

‹› Secure battery seating.

CAUTION!
Risk of explosion, inadequate crash safety, risk of corrosion, shortened service life.

‹› A lose battery retaining bracket can damage the battery housing and allow battery acid to leak.

‹› A battery that is mounted incorrectly can sustain vibration damage resulting in damage to the battery plates.

‹› Tighten retaining bracket bolt.

Risk of malfunction in the electrical system or wiring burn.

‹› Wiring connection contact is not guaranteed if the battery terminals are damaged or the battery clamps are loose. Check the

condition of the battery terminals; battery terminal clamp and auxiliary clamp tightening torque => Starting and Charging See: .

Absorbent Glass Mat Battery, Checking|Page 7768 > < Absorbent Glass Mat Battery, Checking