Cleaning ATF pipes
Cleaning ATF pipes
Special tools and workshop equipment required
   
t  Used oil collection and extraction unit -V.A.G 1782-
t  Hose, approx. 18 mm dia.
t  Compressed air gun (commercially available)
t  Safety goggles
Procedure
  Note
Rules for cleanliness when working on the automatic gearbox → Chapter.
–  Before fitting a replacement gearbox, always blow through the ATF cooler and ATF lines with compressed air (not more than 10 bar).
  Note
If the ATF which emerges during cleaning is very dirty, the ATF cooler and ATF lines must additionally be flushed out with clean ATF.
  W00-10211

Exploded view - selector lever handle, selector lever position display Y26 > < Exploded view - tunnel cross member, gearbox mounting and gearbox support