| Seal off open return line connection with a plug -1-. |
–
| Attach a suitable hose -2- to open return line connection. |
–
| Hold end of this hose -2- in a suitable container to measure return flow rate. |
–
| Perform check at starting speed. |
l
| Specification: return flow rate = 0 ml at starting speed |
If specification is not obtained, fuel pressure regulating valve -N276- is defective. |
|
|
|