t
| Battery charger -VAS 5906- |
Note t
| When charging with battery charger -VAS 5095A-, the current draw of the battery must be measured using e.g. trigger clamp, 100A -VAS 5051B/7-. Battery chargers -VAS 5900-, -VAS 5903-, -VAS 5904- and -VAS 5906- indicate the current draw on the unit. |
l
| Battery temperature must be at least +10 °C. |
l
| The battery charger must be capable of supplying a charging current of at least 30 A, as is the case for example with the battery chargers -VAS 5095A-, -VAS 5900-, -VAS 5903-, -VAS 5904- and -VAS 5906-. |
l
| Battery charger connected and switched on |
–
| Measure battery charging current after a charging period of 5 minutes. |
l
| Specification: Charging current must be greater than 10 % of rated capacity. |
l
| Example: Charging current for a 60 Ah battery after 5 minute charging period: greater than 6 A. |
–
| If reading matches specification, continue with charging process until battery is fully charged. |
–
| Then check battery using the battery tester: |
t
| Using battery tester with printer -VAS 6161- (no waiting time) → Chapter. |
t
| Using battery tester with printer -VAS 5097A- (after charging, wait for 12 hours) → Chapter. |
Note Observe disposal regulations if battery has to be renewed → Anchor. |
|
|
|