audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Outside Air Temperature Sensor Test Requirements|Page 7567 > < Outside Air Temperature Sensor Test Requirements|Page 7565
Page 3
background image

‹› The display field will show that the A/C is working in the fresh air mode.

‹› If a different "fresh air operation" value is displayed in the measured values block, then a request for air recirculation is already present (for

example, manually set to maximum cooling or recirculation), select a mode which does not require air recirculation. 

‹› If is appears in the measured values block that the Air Quality Sensor (G238) is already requesting automatic air recirculation, then, if necessary,

clean the plenum chamber or move the vehicle into an area where the air is cleaner. Refer to Vehicle Diagnosis, Testing and Information System
VAS 5051 in "Guided Fault Finding" function.

-

Allow a little bit of gas from the lighter flow past - B - from the top area - A - of the Air Quality Sensor (G238).

-

Read the recirculation/fresh air mode display.

Specified Values

‹› In the measured values block, it will be displayed that a request for air recirculation is present and that the A/C system is working in the air

recirculation mode.

‹› If is shows in the measured values block that the Air Quality Sensor (G238) has requested automatic air recirculation, this request will not be

performed based on a shut-off requirement from the Climatronic Control Module (J255), A/C control head. Repair cause for this switch off
condition. Refer to Vehicle Diagnosis, Testing and Information System VAS 5051 in "Guided Fault Finding" function.

‹› In order to avoid frequent shifting of the recirculated air/fresh air doors and the recirculation doors, the requirement of the Sensor for Air Quality

(G238)sensor for "Automatic air recirculation " mode remains for at least 25 seconds (minimum duration period), even if the pollutant
concentration is so far reduced that recirculated air mode is no longer necessary.

-

Wait a short period time, approximately. 1 minute, depending on amount of test gas flowing into the sensor.

‹› If the measured value block shows that there is no longer a request for air recirculation, then the A/C system is working again in the fresh air mode.

If the function of Air Quality Sensor (G238) is OK for this test and there is a customer complaint continue as follows:

-

Check the dust and pollen filter for soiling, refer to => [ Dust and Pollen Filter ] See: Service and Repair/Removal and Replacement/A/C System
Control and Regulation Components.

-

With the ignition switched off, connect the Diagnostic Operation System (VAS 5051/) with Diagnostic Cable - 3 Meter (VAS 5051/5A) to the
16-pin Data Link Connector (DLC) of vehicle and perform the self diagnosis and Vehicle Diagnosis, Testing and Information System VAS 5051
in "Guided Fault Finding" function.

-

Using the Vehicle Diagnosis, Testing and Information System VAS 5051 select "Read measured value block" Vehicle Diagnosis, Testing and
Information System VAS 5051 in "Guided Fault Finding" function.

‹› Second person is required to read out values displayed whilst driving. 

Always pay attention to the safety instructions

Outside Air Temperature Sensor Test Requirements|Page 7567 > < Outside Air Temperature Sensor Test Requirements|Page 7565