Evaporator Core: Procedures

Cleaning Evaporator

Special tools, testers and auxiliary items required

‹› Ultrasonic HVAC Cleaning System (VAS 6189). 

‹› Cleaning Fluid (VAS 6189/1)

Preparation

-

Check whether odor is actually in A/C evaporator by switching from fresh air to recirculation.

‹› The odor can only be fixed by cleaning with the Ultrasonic HVAC Cleaning System (VAS 6189) if it originates in the evaporator.

-

Check the plenum chamber and the water drain valves for dirt and debris; clean if necessary, refer to => [ Plenum Chamber Water Drain, Checking
and Cleaning ] See: Testing and Inspection/Plenum Chamber Water Drain, Checking and Cleaning. 

-

Remove the dust and pollen filter and check for odors and dirt, refer to => [ Dust and Pollen Filter ] See: Service and Repair/Removal and
Replacement/A/C System Control and Regulation Components.

‹› On this vehicle, the dust and pollen filter is installed between Fresh Air Blower (V2) and evaporator, therefore it must be removed for the cleaning.

-

Clean the installation compartment of the A/C dust and pollen filter (remove leaves, dust and other contaminants), refer to => [ Dust and Pollen
Filter ] See: Service and Repair/Removal and Replacement/A/C System Control and Regulation Components.

-

Reseal opening on A/C unit through which dust and pollen filter was removed.

-

Start engine.

-

On the A/C Control Head Climatronic Control Module (J255) set "air recirculation" and switch off the compressor (the light in the AC button does
not illuminate). 

-

Open instrument panel vent and set the lowest temperature possible on the Climatronic Control Module (J255) A/C control head ("Cold"
temperature setting).

-

Closes the windows and sunroof.

-

Set Climatronic Control Module (J255) A/C control head to lowest fresh air blow level and select "Instrument panel vent" for air flow direction.

Cleaning

-

Shake the bottle of Cleaning Fluid (VAS 6189/1) and pour the contents into the Ultrasound A/C Cleaner (VAS 6189) (when doing this, be sure to
read the operation manual which comes with the Ultrasound A/C Cleaner (VAS 6189)).

-

Place the Ultrasonic HVAC Cleaning System (VAS 6189) in the passenger's footwell.

-

Start Ultrasonic HVAC Cleaning System (VAS 6189) (according to operating instructions) and route outlet hose belonging to it so vapor escaping
via A/C unit recirculated air opening (in passenger's footwell behind glove compartment) is drawn in by Fresh Air Blower (V2).

-

Close the vehicle doors.

‹› The cleaning process takes about 15 to 20 minutes. It is complete when vapor no longer comes out of outlet hose.

Finishing steps

-

Switch off the Ultrasonic HVAC Cleaning System (VAS 6189).

-

Open the vehicle doors and air out the passenger compartment for at least 10 minutes.

-

Remove Ultrasonic HVAC Cleaning System (VAS 6189) from vehicle and clean it according to operating instructions. 

-

Switch off ignition.