Install both bolts - B - and - H - equally far enough so that both refrigerant lines - C - and - D - can be turned without pretension.

‹› When installing the bolts - B - and - H - be careful not to twist the bracket - A - together with the refrigerant lines.

-

Connect the expansion valve mounting plate - A - to the refrigerant lines - B - and - C -.

-

To align both refrigerant lines, first install the expansion valve and the refrigerant line with the inner heat exchanger. Refer to => [ Expansion
Valve ] See: Compressor HVAC/Service and Repair and=> [ Refrigerant Lines with Inner Heat Exchanger ] See: Compressor HVAC/Service and
Repair.

‹› The expansion valve and the refrigerant line the inner heat exchanger are installed first to align both refrigerant lines leading to the evaporator, and

after tightening both bolts on the evaporator connect, they are removed again.

-

Tighten the bolts - B - and - H - on the evaporator connector (tightening specification 5 Nm). 

-

Remove the refrigerant line with the inner heat exchanger and the expansion valve again.

-

Install the expansion valve. Refer to => [ Expansion Valve ] See: Compressor HVAC/Service and Repair. 

-

Install the refrigerant line with inner heat exchanger. Refer to => [ Refrigerant Lines with Inner Heat Exchanger ] See: Compressor HVAC/Service
and Repair.

-

Install the cover for the evaporator refrigerant lines - B - and the bolt - A -.