A5 Quattro Coupe V6-3.2L (CALA) (2009)
-
Using a multimeter, check the Heated Oxygen Sensor (HO2S) (G108) terminals 3 to 5 for resistance.
Specified value: 2.5 to 10.0 ohms (at approx. 20° C)
If the specification was not obtained:
-
Replace the Heated Oxygen Sensor (HO2S) (G108). Refer to the appropriate service information.
If the specification was obtained:
Checking voltage supply
-
Crank the engine (engine may run).
-
Using a multimeter, check the Heated Oxygen Sensor (HO2S) (G108) electrical harness connector terminal 5 to Ground (GND) for voltage.
Specified value: Battery voltage.
-
Switch the ignition off.
If the specification was not obtained:
-
Check the Heated Oxygen Sensor (HO2S) (G108) electrical harness connector terminal 5 to the Motronic Engine Control Module (ECM) Power
Supply Relay (J271) socket 8 for a open circuit, a short circuit to each other, Battery (+), or Ground (GND).