audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Air Injection Control Valve|Service and Repair > < Version 1|Page 3834
Page 2
background image

-

Connect the Hand Vacuum Pump (VAS 6213) to the vacuum hose for the combination valve to be checked.

-

Remove the front secondary air hose - arrow - from its bracket and disconnect it; to do so press the release buttons.

-

Blow into the Secondary Air Injection (AIR) hose using light pressure (do not use pressurized air).

‹› Secondary Air Injection (AIR) combination valves must be closed, it must not be possible to blow through.

-

Operate hand vacuum pump.

‹› The relevant combination valve must open, it must not be possible to blow through

-

If the secondary air combination valve does not open, replace. Refer to: Left => [ Secondary Air Injection Left Combination Valve ] See: Service
and Repair/Secondary Air Injection Left Combination Valve, right => [ Secondary Air Injection Right Combination Valve ] See: Service and
Repair/Secondary Air Injection Right Combination Valve.

Assembling

Assembly is in reverse order of removal, note the following:

‹› Replace O-ring.

Air Injection Control Valve|Service and Repair > < Version 1|Page 3834