Checking operation

-

Using a jumper, connect AIR pump relay terminals 2 to 8

-

Turn the ignition ON.

-

The AIR pump should be running.

-

Turn the ignition OFF.

If the pump does operate when using a jumper at the relay: 

-

Connect a test lamp to terminal 8 of the AIR relay.

-

Turn the ignition ON.

-

The test lamp should be ON.

-

Turn the ignition OFF.

-

If the test lamp did Not turn on, locate the open circuit between the relay and fuse S130.

-

If the test lamp did turn ON, remove the Motronic Engine Control Module (ECM) (J623). Refer to the appropriate repair information.

-

Using a multimeter, check the AIR pump relay terminal 6 to the Motronic Engine Control Module (ECM) (J623) electrical harness connector T60
terminal 2 for resistance.

Specified value: 1.5 ohms max.

-

If the specified value was not obtained, repair the circuit as necessary. 