Read Measuring Value Block
Read measuring value block
-
Connect VAS5051 tester and select "Engine electronics" function.
-
Press -button.
-
Indicated on display (function selection):
-
Press buttons -0- and -8- to select "Read measuring value block" function 08.
-
Press -Q- button to confirm input. Read measuring value block Help
-
Indicated on display: Input display group number XXX
-
Press buttons -0-, -0- and -8-.
-
Press -Q- button to confirm input.
Display group 008