Service Port HVAC: Description and Operation

NOTES:

-

Use only the specified quick coupling connectors resistant to R-134a and respective refrigerant oils.

-

Connections for the high and low pressure sides have different outside diameters.

-

Before removing the valve or valve stems, discharge refrigerant system. 

-

Always reinstall cap over service valve (with seal).

Connection with Schrader valve (example)

A -

Service connection (lubricated)

B -

Schrader valve stem

C -

O-ring seal

D -

Cap with seal