audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

With Generic Scan Tool|Page 6042 > < With Generic Scan Tool
Page 2
background image

and the sensor should be replaced.

-

End diagnosis and switch ignition off.

If indications do not resemble description:

Checking internal resistance

-

Disconnect harness connector -2- at Engine Coolant Temperature (ECT) Sensor -G2-/-G62-.

-

Connect multimeter between terminal C and D of sensor for resistance measurement.

Range A displays resistance values for the temperature range of 0...50 degree C, range B displays resistance values for the temperature range of 50...100
degree C

Read-out examples:

-

30 degree C corresponds to a resistance of 1500 to 2000 Ohms

-

80 degree C corresponds to a resistance of 275 to 375 Ohms

If specified value is not obtained:

-

Replace Engine Coolant Temperature (ECT) Sensor -G62- -item 20-.

If specified value is obtained:

Checking wire connections

-

Connect test box to wiring harness of Engine Control Module (ECM); ECM is not connected. See: Testing and Inspection/Reading and Clearing

With Generic Scan Tool|Page 6042 > < With Generic Scan Tool