A6 V6-3.0L (AVK) (2004)
13
Overflow hose
14
Fuel filler tube
-
with reservoir with valves and hoses
-
can only be replaced as complete unit
15
Bolt M8 x 30 with permanent washer
-
Tighten to 23 Nm
Fig. 1 Installation position of Ground (GND) connection
NOTE: Check the installation position with fuel tank/fuel filler tube removed.
-
Route Ground (GND) connection (arrow) as shown in figure.
-
Ensure connector of Ground (GND) connection fits securely at metal ring of fuel filler tube.
-
Check whether contact is locked at edge of securing hole.
-
Bolt wire contact -1- with securing bolt -2- for fuel filler tube.
CAUTION: After installing, check electrical connection of metal ring at fuel filler tube to a blank portion of chassis using Ohm meter:
-
Specified value: approx. 0 Ohms.