A6 V6-3.0L (AVK) (2004)
-
Repeat test at another terminal of fuse socket.
If specified values are not obtained again:
-
Check wire connections for open circuit according to wiring diagram:
-
Specified value: Wire resistance max 1.5 Ohms
If no malfunctions are detected:
-
Replace Fuel Pump (FP) Relay -J17-.
-
Re-insert the fuses.
Final procedures
After repair work, the following work steps must be performed in the mentioned sequence:
1
-
Check DTC memory, Diagnostic mode 3 - Check DTC memory. See: Computers and Control Systems/Testing and Inspection/Scan Tool
Testing and Procedures/Scan Tool Testing/With Generic Scan Tool/Diagnostic Mode 3: Check DTC Memory
2
-
Erase DTC memory, diagnostic mode 4 - Reset/erase diagnostic data. See: Computers and Control Systems/Testing and Inspection/Scan Tool
Testing and Procedures/Scan Tool Testing/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase Diagnostic Data
3
-
Generate readiness code. See: Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness
Codes/Audi Drive Cycle/Readiness Code/With Generic Scan Tool/Readiness Code, Generating
-
End diagnosis and switch ignition off.