audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Vehicle Damage Warnings > < Additional Safety Precautions For Side Curtain Airbags|Page 14071
Page 1
background image

Air Bag: Technician Safety Information
Safety Precautions When Working on Airbags

Safety Precautions When Working On Airbags

-

Testing, removing, installing and repair work must only be performed by qualified personnel.

-

Never use test lamp, voltmeter or ohmmeter for testing.

-

Airbag system must only be checked in its installed position using VAG 1551/1552 scan tool.

-

When working on the airbag system, the battery Ground (GND) strap must be disconnected.

-

No waiting time is necessary after disconnecting the battery.

-

When connecting the airbag system to a voltage source, there must not be anyone inside the vehicle.

-

The airbag units should be installed immediately after removing them from their packaging.

-

If the work is interrupted, the airbag unit should again be placed in its packaging.

-

Do not leave the airbag unit unattended.

-

Airbag units which have been removed should be stored so that the padded side is facing up.

-

Do not open or attempt to repair airbag components. Always use new components.

-

Airbag units which have dropped onto a hard surface or show signs of damage must not be installed in the vehicle.

Always observe the following sequence when replacing an airbag unit:

1

-

Remove old airbag unit and lay down with padded side facing up, for side curtain airbag.

2

-

Remove new airbag unit from packaging and set down with padded side facing up, for side curtain airbag.

3

-

Immediately place old airbag unit in packaging

4

-

Install new airbag unit in vehicle.

-

Airbag units have a limited service life (a sticker showing the replacement date is attached to the B-pillar). When an airbag unit is replaced, pull
the sticker off the new airbag unit and stick it over the old sticker on the B-pillar. Airbag units and sticker must be replaced after 14 years.

-

If the vehicle does not have a sticker on the B-pillar, an entry must be made in the Service Schedule to record the airbag replacement.

-

Airbag units which have not been activated should be marked and returned to the manufacturer for disposal (use airbag unit transport container).

-

Never treat airbag units with grease, cleaning agents or the like. An airbag unit must never to be exposed to temperatures in excess of 100 °C (212 
°F)
 (even for brief periods).

Vehicle Damage Warnings > < Additional Safety Precautions For Side Curtain Airbags|Page 14071