background image

Display Group 004

If display zone 3 shows an implausible value: 

-

Disconnect connector -2- at Engine coolant temperature (ECT) gauge/Engine coolant temperature (ECT) sensor -G2-/-G62-. 

-

Connect multimeter between terminals degree C and D of sensor to measure resistance. 

Range A shows resistance values for temperature range 0 to 50 degree C and range B shows the values for temperature range 50 to 100 degree C

Sample readings: 

-

30 degree C corresponds to a resistance of 1500 to 2000 Ohms

-

80 degree C corresponds to a resistance of 275 to 375 Ohms

If specified value is not obtained: 

-

Replace coolant temperature sensor. 

If specified value is obtained: 

-

Connect test box VAG 1598/31 to wiring harness for engine control module; do not connect engine control module. See: Powertrain
Management/Computers and Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Scan Tool Testing/With Manufacturer's
Scan Tool/Scan Tool Connecting and Initial Checks/Connecting VAS 5051 Scan Tool