audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fuel Supply System|FWD|Page 2064 > < Fuel Supply System|FWD
Page 2
background image

6

Tensioning ring

7

Cap

8

Seal
-

Replace if damaged

9

Ground (GND) connection
-

For discharging electrostatic charge

-

Installed position/check requirements, See Fig. 1.

-

Ensure secure seating of connector and secure wire with securing bolt for fuel filler neck -item 3 -

-

After installing, check electrical connection of metal ring at fuel filler tube to a blank portion of chassis using Ohm meter
Specified value: approx. 0 Ohms

10

Vent line
-

to EVAP canister

11

Vent line

12

Vent line

13

Fuel tank

14

Tension strap
-

Note varying lengths

-

Installation position: Locating point (hole) faces direction of travel

15

Bolt M8 x 28 with permanent washer
-

Tighten to 23 Nm

Part II

Component Locations, Overview

1

Fuel filler tube
-

with reservoir 

2

O-ring
-

replace

3

Gravity valve
-

not available separately as replacement part

-

To remove, unclip valve upward from fuel filler tube

Fuel Supply System|FWD|Page 2064 > < Fuel Supply System|FWD