A6 V6-3.0L (AVK) (2004)
6
Tensioning ring
7
Cap
8
Seal
-
Replace if damaged
9
Ground (GND) connection
-
For discharging electrostatic charge
-
Installed position/check requirements, See Fig. 1.
-
Ensure secure seating of connector and secure wire with securing bolt for fuel filler neck -item 3 -
-
After installing, check electrical connection of metal ring at fuel filler tube to a blank portion of chassis using Ohm meter
Specified value: approx. 0 Ohms
10
Vent line
-
to EVAP canister
11
Vent line
12
Vent line
13
Fuel tank
14
Tension strap
-
Note varying lengths
-
Installation position: Locating point (hole) faces direction of travel
15
Bolt M8 x 28 with permanent washer
-
Tighten to 23 Nm
Part II
Component Locations, Overview
1
Fuel filler tube
-
with reservoir
2
O-ring
-
replace
3
Gravity valve
-
not available separately as replacement part
-
To remove, unclip valve upward from fuel filler tube