audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Battery With Charge Indicator|Page 11553 > < Battery With Charge Indicator|Page 11551
Page 1
background image

Battery: Testing and Inspection
Open Circuit Voltage, Measuring

Open Circuit Voltage, Measuring

Special Tools and Equipment

-

VAG 1526A

WARNING!
Battery plugs must always be threaded in so they seal properly for charging, voltage measurement and load measurement.

Make sure the following notes are observed, since a proper measurement can otherwise not be ensured.

NOTE:

-

If the open-circuit voltage is being measured on a battery installed in a vehicle, it is imperative to disconnect the Ground (GND) strap.

-

Power-consuming devices must not be connected to the battery for at least 2 hours before the measurement is taken.

-

Loads may not be applied to the battery for at least 2 hours before the measurement is taken.

Procedure

NOTE:

-

Obtain radio code before disconnecting battery.

-

Be sure to activate vehicle features (radio, clock, electric window regulator, engine) when the battery is re-connected.

-

Remove cover above the battery (arrows).

NOTE:  For vehicles without separate battery cover: Remove plenum cover.

Battery With Charge Indicator|Page 11553 > < Battery With Charge Indicator|Page 11551