audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Condenser HVAC|Locations|Page 21072 > < Condenser HVAC|Locations|Page 21070
Page 3
background image

-

Only install accumulator with insulation -E-.

-

Install spring -F- so it is positioned against marking on refrigerant hose and engaged on bracket

Version "3" (with two block connections), removing

-

Remove bolts -A- (tightening torque 25 Nm) and remove refrigerant lines -B- and -C-.

NOTE:

-

Replace both O-Ring-seals -D- and -E- (16.7 mm x 1.8 mm).

-

Seal all open connections.

-

The connection on the accumulator can be marked with "IN" (from evaporator) and "OUT" (to compressor).