A6 Quattro Sedan V6-2.7L Turbo (APB) (2000)
-
Replace Secondary Air Injection (AIR) pump relay -J299-.
Check voltage supply of the Secondary Air Injection (AIR) pump motor
-
Remove connector for Secondary Air Injection (AIR) pump motor -V101-.
-
Connect VAG1527B voltage tester between terminals 1 and 2
-
Initiate output Diagnostic Test Mode (DTM) and activate Secondary Air Injection (AIR) pump relay -J299-
-
LED must blink.
If LED does not blink:
-
Perform following tests marked with dots:
-
Check wire connection from connector at Secondary Air Injection (AIR) pump motor -V101- to Secondary Air Injection (AIR) pump relay
-J299- (in 3-socket relay carrier in E-Box, plenum chamber, position 2) for open circuit.
-
Check wire connection from connector at Secondary Air Injection (AIR) pump motor -V101- to Ground (GND) connection 1 in engine
compartment wiring harness for open circuit:
If no malfunctions are detected:
-
Replace Secondary Air Injection (AIR) pump motor -V101-