Connect hand-held multimeter (voltage range) to terminal 15 of harness connector and Ground (GND).

-

Disconnect harness connector from fuel injector of cylinder to be tested.

-

Operate starter. 
Specification: approx. battery voltage

If the specification is not obtained:

-

Check wiring.

If the specification is obtained:

-

Disconnect 3-pin harness connectors on power output stages for ignition coils. 

-

Then connect diode test lamp to 3-pin connectors for both output stages.

-

Connect diode test lamp VAG1527 to following contacts on connectors for power output stages:

3-pin harness 

Specification (with 

connector terminal

starter activated)

1 + Ground

Diode test lamp (GND) should 

2 + Ground (GND)

light up

3 + Ground (GND)

If the specifications are not obtained:

-

Switch ignition off.

Check the following wiring connections for open circuits and/or short to B+ or Ground (GND).

Black 3-pin 

3-pin connector 

connector on

on ignition coil 

power output stage, terminal

terminal

1

1 (cylinder 1)