Check fuse S234 (in fuse holder, position 34).

-

Check wire connection from exhaust gas temperature sensor via fuse S234 (in fuse holder, socket 34) to Fuel Pump (FP) relay for open circuit:

-

Check Fuel Pump (FP) relay.

-

Connect VAG1598/31 test box at wiring harness to ECM, do not connect ECM.

-

Check following wire connections for open circuit and short circuit to Ground (GND) and B+:

Harness connector

VAG1598/31 test box

terminal

Bushing

1 (Bank 1)

61

1 (Bank 2)

20

2

50

If wire connection is OK:

-

Replace exhaust gas temperature sensor.

If the same malfunction occurs again after replacing the exhaust gas temperature sensor:

-

Replace Engine Control Module (ECM).