Complete measuring bar as shown in illustration.

-

VW385/15 extension pin 9 mm

-

VW385/30 master gauge, adjusting
^

Ro = 57.50mm

-

Set dial indicator (3 mm measuring range) to 0 with 2 mm preload.

Note:  Turn differential at least 5 rotations in each direction to seat the tapered roller bearings. Otherwise, measurement will result in false
readings.    

-

Install VW385/33 end gauge of drive pinion head.

-

Remove master gauge and insert measuring mandrel into housing.