Complete measuring bar as shown in illustration.
-
VW385/15 extension pin 9 mm
-
VW385/30 master gauge, adjusting
^
Ro = 57.50mm
-
Set dial indicator (3 mm measuring range) to 0 with 2 mm preload.
Note: Turn differential at least 5 rotations in each direction to seat the tapered roller bearings. Otherwise, measurement will result in false
readings.
-
Install VW385/33 end gauge of drive pinion head.
-
Remove master gauge and insert measuring mandrel into housing.