audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Using the OTC Oil Service Reset Tool|Page 1550 > < Using the OTC Oil Service Reset Tool|Page 1548
Page 5
background image

Channel 8 Adaptation 66 Q
Input adaptation value XXXXX

- Enter Adaptation value between 0 days (00000) and 730 days (00073). The value can be entered in steps of 10 days. Example: 730 days, therefore

enter 00073.

- Press -Q- button to confirm input.

Channel B Adaptation 73 Q
Store changed value?

- Press -Q- button to confirm input.

Channel 8 Adaptation 73 Q
Changed value stored

- Press button to end coding.

Rapid data transfer HELP
Select function XX

- Press buttons -1- and -0- to select "Adaptation" function 10.

Rapid data transfer Q
10 - Adaptation

- Press -Q- button to confirm input.

Adaptation
Insert channel number XX

Instrument cluster, setting SRI and mileage

Note:

Instrument cluster must be coded before setting if it was replaced.

- Press button -1- to select "Rapid data transfer" operating mode 1.

Rapid data transfer HELP
Insert address word XX

- Press buttons -1- and -7- to insert "Instrument Cluster" address word 17.

Rapid data transfer Q
17 - Instrument Cluster

- Press -Q- button to confirm input.

Rapid data transfer
Scan Tool sends address word 17

- After 5 seconds the display indicates a part number and the control module code.

4D0 919 033 C4 Instrument cluster D03 coding 00262 WSC 06812

- Press -> button.

Rapid data transfer Q
Select function XX

- Press buttons -1- and -0- to select "Adaptation" function 10.

Rapid data transfer Q
10 - Adaptation

Using the OTC Oil Service Reset Tool|Page 1550 > < Using the OTC Oil Service Reset Tool|Page 1548