audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Using the OTC Oil Service Reset Tool|Page 1554 > < Using the OTC Oil Service Reset Tool|Page 1552
Page 9
background image

06 - End Output

- Press -Q- button to confirm input.

Rapid data transfer HELP
Select function XX

Instrument cluster, replacing General notes

Before removing instrument cluster, note vehicle mileage

After replacing the instrument cluster, the vehicle mileage and all SRI indicators are to be re-established/coded into the new cluster.

Note the Airbag safety information, where applicable.

Functional tests of the instruments should be conducted.

See applicable wiring diagram for routing of terminals and checking multi-pin connectors.

Test requirements

Fuses OK, check according to wiring diagram.

Always check the coding of the instrument cluster with VAG 1551 scan tool.

Note: "Automatic Test Sequence" function 10 is not possible with VAG 1551 scan tool with software status 4.0 (version 4.0 card). The control

modules should be checked individually using their respective address words. with the update of test software this function will be possible.

Using the OTC Oil Service Reset Tool|Page 1554 > < Using the OTC Oil Service Reset Tool|Page 1552