audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Idle Speed|Specifications|Page 1251 > < Idle Speed|Specifications
Page 1
background image

Idle Speed: Adjustments

Test conditions 

-

No leaks in exhaust system.

-

Engine Coolant Temperature (ECT) minimum 85°C (185°F).

-

Throttle valve in closed throttle position. Adjust accelerator pedal cable if necessary.

-

All electrical consumers switched OFF.

-

A/C switched OFF.

-

Pressure measuring devices NOT connected.

-

Automatic transmission vehicles: selector lever in P or N.

Checking Idle Speed 

NOTE:

Idle speed cannot be adjusted.

-

Connect VAG 1551 scan tool. Refer to Connecting and Operating VAG Scan Tool. See: Powertrain Management/Computers and Control
Systems/Testing and Inspection/Scan Tool Testing and Procedures/Scan Tool Testing/Scan Tool Connecting and Initial Checks/Connecting
and Operating VAG Scan Tool

-

Step through program until "Select function XX" display appears. Display will appear as shown:

Rapid data transfer   

HELP

Select function   XX 

-

Check DTC memory.
^

There should be no malfunctions stored.

-

If necessary, repair malfunction, erase DTC memory, stop engine (switch ignition OFF) and start again. Test drive and check DTC memory
again to make sure no malfunctions are stored.

-

After checking DTC memory, let engine continue to idle.

CAUTION! 

^

Do not take any measurements while the radiator coolant fan is running. 

^

Engine coolant temperature must be 85°C (185°F) minimum. 

Display will appear as shown:

Rapid data transfer   

HELP

Select function   XX 

-

Press buttons 0 and 8 to select "Read Measuring Value Block" function 08.  

Display will appear as shown:

Rapid data transfer   

Q

08 - Read Measuring Value Block 

-

Press Q button to confirm input.

Display will appear as shown:

Read measuring value block   

HELP

Input display group number XXX 

-

Press buttons 0, 0 and 3 to select display group 003.

Display will appear as shown:

Rapid data transfer   

Q

Input display group number 003 

-

Press Q button to confirm input.

Display will appear as shown:

Read measuring value block 

3

1      2      3      4. 

-

Read idle speed in display field 1.
^

Specified value: 650-750 RPM 

-

Press "arrow" button.

Idle Speed|Specifications|Page 1251 > < Idle Speed|Specifications