A6 Quattro Sedan V6-2.8L (AHA) (1998)
NOTE:
-
Install refrigerant lines free of stress and make sure there is enough clearance to other components.
-
When installing the accumulator in the bracket, always install insulation -F-.
Version "2" (with block and bolt connection), removing
-
Remove hexagon nuts -A- (tightening torque: 8 Nm).
-
Remove bolts -B- (tightening torque:25 Nm).
-
Remove refrigerant line -C- (tightening torque: 40 Nm).
-
Remove refrigerant line -D-.
NOTE:
-
Replace O-rings -E- (17.2 mm x 1.8 mm) and -F- (16.7 mm x 1.8 mm).
-
Seal all open connections.
-
Remove hexagon nuts -A-.
-
Loosen clamp -B-
-
Remove bracket -C-
-
Remove hexagon nuts -D- (tightening torque: 8 Nm).
NOTE: