Remove bolts -A- (tightening torque: 8 Nm).

-

Loosen notch on bracket for accumulator -B- from body

-

Remove accumulator with bracket.

-

Loosen screw -C- (tightening torque 8 Nm) and remove accumulator from bracket -D-.

Installing (all models)

Before installing accumulator:

NOTE:

-

When tightening refrigerant lines to accumulator hold accumulator e.g. with oil filter strap (to avoid accumulator from turning).

-

Install refrigerant lines free of stress and make sure there is enough clearance to other components.

-

Keep accumulator closed as long as possible; do not remove caps until just before installing. The accumulator contains a desiccant which will
become saturated with moisture in a short time if accumulator is left open. This makes the accumulator unusable.

-

Removed accumulator contains refrigerant oil which must be restored to the refrigerant system (with new accumulator).

-

The adaptation of the oil capacity depends on the type of report:
-- For example if the accumulator was damaged (no refrigerant escaped, no moisture or dirt entered the system), the air conditioning system can

be repaired by weighing the old and the new accumulator: Fill new accumulator with refrigerant oil, until the weight of the removed
accumulator is reached.

-- If an undefined amount of refrigerant oil escaped or dirt and moisture entered the system, clean refrigerant circuit with compressed air and

nitrogen

Installation is in reverse order of removal, observe notes and tightening torque for respective version (see removing notes)

-

Install all removed components again.

-

 Evacuate and recharge refrigerant circuit.