audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

LED Test Light|Page 19938 > < LED Test Light|Page 19936
Page 1
background image

Refrigerant Pressure Sensor / Switch: Description and Operation

A/C Pressure Switch -F129-

Functions

-

At low or high pressure in the refrigerant circuit the low/high pressure switch (switch between terminals 1 and 2) switches the compressor off (via
A/C Control Head -E87-).
-

Switching pressures (in bar high pressure):
-

Switch open (compressor off):
Low pressure switch (opens at 1.2 bar and closes at 1.8 bar).
High pressure switch (opens at 30 bar and closes at 14.5 bar).

-

Switch closed (compressor on):
1.2 (1.8) bar to 30 (14.5) bar.

-

Coolant Fan -V7- is switched to second speed via the high pressure switch (switch between contact 3 and 4).
-

Switching pressures (in bar high pressure):
-

Second speed of coolant fan engages at 16 bar (switch closes).

-

Second speed of coolant fan is switched off at 12.5 bar (switch opens).

LED Test Light|Page 19938 > < LED Test Light|Page 19936