Observe rules of cleanliness (Group 20 of appropriate Engine Repair Manual).
^
Always complete checking procedure (check all 3 sending units).
Fuel Tank, draining
-
Remove fuse 28 from relay panel (left-row, fifth large fuse from top).
-
Start and run engine until engine runs out of fuel (relieves pressure in fuel system).
-
Switch ignition OFF
-
Remove fuel supply hose from sending unit -G- and connect to VAG 1433A fuel cart or similar approved equipment.
-
Connect VAG1348/3 remote switch with VAG1348/3-2 adapter to cavity for fuse 28.
-
Connect test probe to Battery Positive Voltage (B+).
With remote switch connected:
-
Operate switch and pump fuel into fuel cart until tank chambers for sending units -G237- and -G- are empty.
-
Switch OFF VAG1348/3 remote switch and remove VAG1348/3-2 adapter from cavity for fuse 28.
-
Remove test probe from Battery Positive Voltage (B+).