audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Audi A6 Quattro Sedan V6-2.8L (AHA) (1998)|Fluids > < Refrigerant Lines From Denso Compressor|Page 5972
Page 2
background image

-

Replace both O-Ring-seals -C- (14.0 mm x 1.8 mm) and -D- (10.8 mm x 1.8 mm).

-

Close all open lines and connections on condenser with suitable caps (avoid did and moisture from entering the system).

Removing refrigerant lines on version "3" (one block connection on left side and one on right side)

-

Remove bolts -A- (tightening torque 20 Nm).

-

Remove refrigerant line from condenser.

NOTE:

-

Replace both O-Ring-seals -C- (14.0 mm x 1.8 mm) and -D- (11.1 mm x 1.8 mm).

-

Close all open lines and connections on condenser with suitable caps (avoid dirt and moisture from entering the system).

Connecting

Installation is the reverse order of removal, observe notes and tightening torque for respective version (see removing notes)

-

Replace O-ring-seals.

NOTE:

-

When tightening bolts/nuts (on refrigerant lines) on condenser; counterhold condenser to prevent connection from twisting.

-

Install refrigerant lines free of stress and make sure there is enough clearance to other components.

-

Check positions of refrigerant lines -A-, they must be fully engaged in bracket -B- and cannot come in contact with other components (different
versions)

-

Install all removed components again.

-

Evacuate and recharge refrigerant circuit.