Immediately set guide frame in place and align using T40029 locating pin.
Notes:
^
Setting in place and tightening the guide frame should occur without interruptions, since the sealant starts to harden immediately.
^
After installing guide frame, allow sealant to dry for approximately 30 minutes.
-
Tighten bolts of guide frame in the sequence of the numbers and follow arrows uniformly by hand.
^
Guide frame must make full contact with cylinder head surface
-
Tighten bolts of guide frame to final tightening torque (10 Nm).