Air Door Actuator / Motor: Service and Repair
Defroster Flap Motor -V107-

Defroster Flap Motor -V107-, Removing And Installing

-

Remove glove box

-

Disconnect harness connector -A-.

-

Remove 3 bolts -B-.

-

Disengage actuating arm and remove positioning motor.

NOTE:  The lever arm of the stepper motor installed on the version "2" air conditioning unit is different from the arm installed on version "1".

-

Remove bolts -C- (3x) and detach positioning motor -B- from bracket -D-.

Notes for installation:

-

After installing, always carry out On Board Diagnostic (OBD) of air conditioning system.

-

When installing the positioning motor, make sure that the actuator arm is properly engaged.

-

Install the wiring harness so that it cannot come in contact with any moving parts (e.g. the actuating arm on the positioning motor).