audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Complete Air Conditioner Unit, Removing and Installing|Page 12607 > < Complete Air Conditioner Unit, Removing and Installing|Page 12605
Page 2
background image

6. Evaporator

With seal
From version "2", the width of the evaporator is 32 mm less than the width of the evaporator in version "1".
Starting with version "2", the evaporator can no longer be removed from the air distributor housing (the housing must be disassembled, due to the
changed refrigerant line connection).

7. Bolt

8. Refrigerant lines

With insulation
Refrigerant lines from version "2" were adapted to the modified evaporator
After assembly, refrigerant lines and connector flange of evaporator must be wrapped completely with foam (for insulation)

9. Bracket
10. Bolt

11. O-ring seals

Always replace

Check for correct diameter
Different diameters, version "1":

2 piece 13.4 mm x 2.4 mm

From version "2":

1 piece 13.4 mm x 2.4 mm
1 piece 10.8 mm x 2.4 mm

12. Central Air Flap Motor -V70-

With Potentiometer actuator for temperature flap left -G112-
Removing and installing   See: Air Door/Air Door Actuator / Motor/Service and Repair

13. Bolt

14. Actuator for temperature flap right -V159-

With Potentiometer actuator for temperature flap left -G221-
Removing and installing   See: Air Door/Air Door Actuator / Motor/Service and Repair

15. Defroster flap motor -V107

With Potentiometer actuator for temperature flap left -G135-
The lever arm on Defroster Flap Motor -V107- is different between air conditioning units "1" and "2".
Removing and installing   See: Air Door/Air Door Actuator / Motor/Service and Repair

16. Bolt
17. Bracket for Defroster Flap Motor -V107-

18. Air distribution housing

Do not disassemble further
- On vehicles that do not have additional heater element -Z35- the opening for the heater is closed. On air distributor housing units supplied as
replacement parts the opening is open; if used on vehicles which do not have additional heater elements, the opening must be closed off using cap
-29-
- Housing, air flaps, drip pan, evaporator and various other parts are different in versions "1 and "2"
- On air conditioning version "1", the air guide to the intermediate piece (spacer) for defroster channel has two openings. Starting from version "2"
the two openings have been combined into one opening.
- The position of the central flaps is different. From version "2", when the center flap is closed the two outer flaps remain slightly open (angle
between both flaps approx. 40 degrees). On version "1" all flaps close simultaneously.
- Version "3" has an additional opening for the installation of Evaporator Vent Temperature Sensor -G263-. (On vehicles without Evaporator Vent
Temperature Sensor -G263- this opening is closed with a plug).

19. Coolant pipe

Return tube 

20. Coolant pipe

Supply tube

21. Bracket for refrigerant lines

Complete Air Conditioner Unit, Removing and Installing|Page 12607 > < Complete Air Conditioner Unit, Removing and Installing|Page 12605