A6 Quattro Sedan V6-3.0L (AVK) (2002)
-
Remove bolts for holding plate for solenoid valves (arrows).
-
Lift up holding plate and disconnect vacuum hose from Y-piece of combination valve to be checked.
-
Connect VAG1390 hand vacuum pump to vacuum hose of combination valve to be checked.
-
For vehicles with auxiliary heater, remove bolts (arrows) for exhaust pipe of parking heater/auxiliary heater at noise insulation.