Canister Purge Control Valve: Testing and Inspection

Evaporative Emission (EVAP) Canister Purge Regulator Valve -N80-, Checking

Special tools and equipment

-

VAG 1526A

-

VAG 1527B

-

VAG 1594A

-

VAG 1598/31

-

VAS5051 with VAS5051/1

Checking for leaks

When there is no electrical supply, solenoid valve remains closed.

-

Disconnect hoses from EVAP canister purge regulator valve but leave electrical connector plugged in.

-

Connect auxiliary hose to one connection of EVAP canister purge regulator valve.

-

Connect testing and information system VAS5051 and select vehicle system "01 - Engine electronics". Ignition must be switched on.

-

Initiate Output Diagnostic Test Mode (DTM) and activate evaporative emission (EVAP) canister purge regulator valve -N80-. See: Computers and
Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Scan Tool Testing/Output Diagnostic Test Mode (DTM) (Function 03)
-

The valve should click ...

-

... and should open and close (check by blowing into auxiliary hose).

-

Press <- button to end function "03 - Final Control Diagnosis", also known as Output Diagnostic Test Mode (DTM).

If valve does not open and close properly:

-

Replace evaporative emission (EVAP) canister purge regulator valve -N80-.

If the injector does not click:

Checking internal resistance

-

Disconnect connector on EVAP canister purge regulator valve.