A6 Quattro Sedan V6-3.0L (AVK) (2002)
Fuel Distance/Mileage Module: Service and Repair
Adaptation (function 10)
individual functions are called up by entering the appropriate adaptation channel numbers (see adaptation table).
NOTE:
-
Using measuring value blocks 010, 011, 012 and 015, the values that need to be transferred to the new instrument cluster can be read out before
replacement.
-
Adaptation channels 42, 43, 44 and 45 (Measuring value blocks 013 ) must be adapted when the instrument cluster is replaced.
-
Adaptation channels 60, 61, and 62 are only needed when the instrument cluster communicates with the corresponding BUS system..
-
Measuring value blocks 125 and 126 indicate the participants in the powertrain CAN-bus.
-
Measuring value block 130 indicates the participants in the comfort system CAN-bus.
-
Measuring value block 140 indicates the participants in the information CAN-bus
Adaptation table
Adaptation channel
Adaptation function
02
Resetting SRI after service
03
Adaptation of consumption display
04
Language versions of driver information system
09
Odometer
18
Adaptation of auxiliary heater
30
Adaptation of fuel gauge sender
35
Adaptation of engine speed threshold
40
Adaptation For distance driven since service
41
Adaptation For time since service
42
Adaptation For minimum mileage performance
43
Adaptation For maximum mileage performance
44
Adaptation For maximum time interval
45
Adaptation For oil quality
60
Adaptation powertrain CAN-bus
61
Adaptation comfort system CAN-bus
62
Adaptation information CAN-bus
Initiating "Adaptation" function 10
-
Initiate output Diagnostic Test Mode of instrument cluster.
Display on VAS5051:
-
In selection -1-, select the diagnostic function "10 - Adaptation".
Display on VAS5051