audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Adaption (Function 10)|Page 2004 > < Adaption (Function 10)|Page 2002
Page 5
background image

1

-

Enter adaptation value input value 0 to 65535

-

Enter 5-digit adaptation value in button field -2-. If necessary, insert zeros in front.

Example:
Desired input value: 1
Keypad input: 00001

-

Press -Q- button to confirm input.

Display on VAS5051:

1

-

Channel X save

2

-

Text display of selected channel or No indication

4

-

original value X new value X

-

Confirm new adaptation value by pressing the "take over" button -3-.

Display on VAS5051:

1

-

Channel X Value X stored

-

End function "10 - Adaptation" by pressing <- button.

Adaptation channel 30 -Adaptation of fuel gauge sender resistance range

This function is used to adjust the fuel gauge sender resistance range if the fuel gauge display in the instrument cluster does not match the actual amount
of fuel in the tank.

Display on VAS5051: