Dip the hydrometer into the battery cell, and draw electrolyte up into it until its floater floats freely in the electrolyte.
-

The larger the specified weight of the syphoned battery acid, the higher the floater will float

-

The specified gravity of the electrolyte can be read off in kg/dm on the hydrometer scale3 (specified gravity of the battery acid)

-

Read off measured value at hydrometer and compare to indicated values in the table:

Charge condition in

Electrolyte density in kg/cubic dm

normal climates
discharged

1.12

half-charged

1.20

good charge

1.28

Charge condition in

Electrolyte density in kg/cubic dm

tropical climates
discharged

1.08 

half-charged

1.16 

good charge

1.23

Specified gravity of electrolyte must be at least 1.24 kg/cubic dm in normal climate zones.

-

If the specified gravity in all battery cells is too low, charge battery.

-

Repeat specified gravity test after charging battery.

-

If the specified values are not reached, replace battery.

NOTE:  The measured values for the acid density for individual battery cells may not deviate more than 0.03 kg/cubic dm from each other, otherwise
replace battery.