A6 Quattro Sedan V6-3.2L (BKH) (2005)
-
Remove the screws - B -.
-
Release the connecting flange - A - (of the refrigerant lines) from the connection flange - D - (at the evaporator - E -).
-
Remove the screw - A - on the bracket for the coolant pipe (to the right at the A/C unit, do not remove), and put the coolant pipe - D - off to the
side.
-
Put on the heavy-duty gloves (to protect your hands when separating the A/C unit housing wall).
-
Separate the housing wall - B - and - C - (on the right side of the A/C unit) using a sharp knife (for example, a strong carpet knife with a point; the
blade must be secure and the handle must be strong.) along the cut line - E - from the A/C unit.
‹› Make sure the flange - F - is not damaged (it seals the cover to the A/C unit).
-
Remove the evaporator - E - to the right from the A/C unit.